Dit is een test-site

Winkelwagen

  • Winkelwagen is leeg!

Merken

curve_type_3_left_tcurve_type_3_right_t
Fiber Optic Cable U-dq(zn)bh 50/125 - Om3 - 24 Fibers

Fiber Optic Cable U-dq(zn)bh 50/125 - Om3 - 24 Fibers

€6,16 
Referentie: DRAKF035
Taal: UK

Uitgebreide beschrijving

Inleiding

DRAKA U-DQ(ZN)BH 50/125 - OM3 - 24 FIBERS BULK CABLE

Specifications

Model: DRAKA 10250408

 

UCFIBRE I/O CT D DA LSHF 1.0 kN 24 OM3 B OM3 MaxCap BB 300 50/125 multimode

 

Application

  • Universal, indoor and outdoor.
  • LAN backbones
  • Telecom access lines.
  • Computer network, campus network

Standards

  • ISO 11801 2nd edition
  • EN 50173-1:2002
  • IEC 60794-1

Construction

  • Loose tube: Central tube with 3.5mm diameter
  • Colour sequence:
      • 1: Red
      • 2: Green
      • 3: Blue
      • 4: Yellow
      • 5. White
      • 6. Grey
      • 7. Brown
      • 8. Violet
      • 9. Turquoise
      • 10. Black
      • 11. Orange
      • 12. Pink
      • 13: Yellow with mark per 70mm
      • 14: White with mark per 70mm
      • 15: Grey with mark per 70mm
      • 16: Turquoise with mark per 70mm
      • 17: Orange with mark per 70mm
      • 18: Pink with mark per 70mm
      • 19: Yellow with mark per 35mm
      • 20: White with mark per 35mm
      • 21: Grey with mark per 35mm
      • 22: Turquoise with mark per 35mm
      • 23: Orange with mark per 35mm
      • 24: Pink with mark per 35mm
  • Reinforcement: Reinforced with glass fibre
  • Sheath: 1.0 mm, FireBur blue, UV-resistance, IEC 50290-2-27

Structure

Loos tube: Loose tube 3.5mm filled with hydrophobic gel with 24 fibres

Strength member: hydrophobic glass fibre insulation

Sheath: 1.0mm blue FireBur, UV-resistant, IEC 50290-2-27

Non-flammability

  • IEC 60332-1-2: Single vertical wire test
  • IEC 60754-1: No halogens
  • IEC 60754-2: No acid matters
  • IEC 61034-2: No dense smoke
  • Heat of combustion: 800 Mj/km; 0.22 KWh/km

 

Mechanical parameters

  • Outer diameter: 6.5mm
  • Weight: 45 kg/km
  • Maximum tesile strength: E1: 1000N (less than 1/2 of fibre strength)
  • Tensile strenght (dynamic): E1: 750N (less than 1/3 of fibre strength)
  • Tensile strenght (static): E1: 500N (no atenuation; less than 1/4 fibre strength)
  • Breaking force: E3: 1500N/dm
  • Impact: E7: 15 Nm (no attenuation; no broken cable elements)
  • Torsion: E7: 5 cycles +/- 1 turn
  • Minimum bending radius (dynamic): E11: R=60 mm
  • Minimum bending radius (static): R=100 mm
  • Temperature range: F1:
      • Storage: -40°C + 70°C
      • Installation: -15°C + 40°C
      • Operation: -40°C + 60°C
  • Water penetration: Resistant to longitudinal water penetration